WAKE COUNTY 911 CAD STREAM: ONLINE (120ms LATENCY)USFA / FEMA NERIS v1.0 CLOUD ENDPOINT: SYNCED · NC OSFM BRIDGE ACTIVE
ISO CLASS 1 READINESS•5 BATTALIONS · 29 RFD STATIONS
CITY OF RALEIGH FIRE DEPARTMENT · BATTALION COMMAND RMS & FEMA NERIS CONSOLEOffline-First iPad MDT + Cloud RMS

Pre-Incident Tactical Floorplan & Hydrant Flow Intelligence, NFPA 1710 Fractal Analytics, and 1-Click USFA FEMA NERIS Reporting

WORKING COMMERCIAL FIRE · TAC CHANNEL 3BBattalion 3 · Downtown & Glenwood South

One Glenwood Mixed-Use High-Rise & Commercial Kitchen Plaza — 410 Glenwood Ave, Raleigh, NC 27603

Type I-A Fire-Resistive Concrete Podium + Mezzanine Steel Truss · 10 Stories · 248,000 Sq. Ft. · Occupant Load: 1,140

BRAVO EXPOSURE STREET (5-INCH SUPPLY HOSE LAY CORRIDOR)ALPHA EXPOSURE (PRIMARY AERIAL TURNTABLE ACCESS)STAIR ASTAIR BSIDE ASIDE B (BRAVO)SIDE CSIDE D (DELTA)KNOX BOX5" STORZ FDCSOLAR PV SHUTHAZMAT TIER IIHYD-RAL-1084 (1680 GPM)HYD-RAL-1089 (1540 GPM)HYD-RAL-1094 (1320 GPM)E1L1E6R1B3
Selected Hydrant: HYD-RAL-1084 (Class AA (1,500+ GPM))NW Corner Glenwood Ave & W North St
Static: 74 PSIResidual: 61 PSIFlow: 1680 GPMDist: 95 ft
Knox Box & FDC Standpipe Access

Recessed Knox Box #3108 at North West St Main Security Vestibule (5 ft AFF)

Dual 5-Inch Storz FDC + High-Zone Standpipe on West Tucker St Exposure

HazMat Tier II, Solar PV & Structural Truss Warnings

1,200 Gal Diesel Emergency Generator Belly Tank (Sub-Level P1 Vault)

Level 2 Restaurant Terrace utilizes lightweight bar-joist steel assembly; Class K Ansul tripped

Dispatched RFD Apparatus & NFPA 1710 Clocks5 Units
E1Station 1 (Dawson St)
Turnout 48s · Travel 174s

Pumping 150 PSI to W Tucker St FDC via HYD-1089

L1Station 1 (Dawson St)
Turnout 52s · Travel 182s

100-ft Aerial Turntable Positioned Alpha/Bravo Corner

E6Station 6 (Fairview Rd)
Turnout 51s · Travel 198s

Interior Attack Line · Stairwell B Standpipe Riser

R1Station 14
Turnout 46s · Travel 205s

Primary Search & Roof Solar PV Isolation

B3Battalion 3 HQ
Turnout 41s · Travel 168s

Glenwood Command Post (Alpha Exposure)

USFA / FEMA NERIS 2026 Schema Inspectorv1.0 Validated
CAD Run: RFD-2026-041982
NERIS Code: NERIS 111.2 — Commercial Structure Fire (Kitchen Exhaust Duct Extension)
PSB / Timestamps: Dispatch, En Route, On Scene, Water-on-Fire Auto-Populated
NFPA 1710 & ISO Class 1 Analytics

90th-Percentile Turnout & First-Engine Travel Time (Seconds) Across Battalions 1–5

Target: ≤60s / ≤240s
Apparatus Pump (NFPA 1911) & Turnout Gear (NFPA 1851) Readiness Ledger
Engine 1 (Pierce Enforcer 1,500 GPM)NFPA 1911 Annual Draft Test Passed (1,540 GPM)18/18 Sets Advanced Inspection & Decon Current
Ladder 1 (100-ft Pierce Ascendant Tiller)NFPA 1911 Aerial Non-Destructive UL Test Passed20/20 Sets Advanced Inspection & Decon Current
HazMat 2 (Heavy Technical HazMat)Level A Vapor Suits Pressure-Tested · PID Calibrated16/16 Sets Particulate Barrier Verified
Offline-First iPad Office of the Fire Marshal Suite

NC Fire Prevention Code Inspection Checklist — One Glenwood Mixed-Use High-Rise & Commercial Kitchen Plaza

Click Item to Toggle Pass/Order
[NCFC § 901.6.1]Automatic Sprinkler & Class I Standpipe Five-Year Hydrostatic Test

High-zone fire pump verified at 1,500 GPM @ 145 PSI; riser tags current.

PASS · COMPLIANT
[NCFC § 607.3]Commercial Kitchen Type I Hood & UL-300 Wet Chemical Suppression

Semi-annual fusible link service verified; grease duct cleanout access unobstructed.

PASS · COMPLIANT
[NCFC § 1205.2]Solar Photovoltaic Rapid-Shutdown Plaque & Roof Perimeter Access Path

36-inch clear perimeter pathway maintained; reflective red AC/DC disconnect signage posted.

PASS · COMPLIANT
[NCFC § 1031.2]Means of Egress Stairwell Pressurization & Panic Hardware

Stairwell B photoluminescent markings and smoke-damper actuators verified.

PASS · COMPLIANT
Offline IndexedDB cache stores annotated photos & occupant signatures in basement mechanical rooms.Synced to Pre-Incident Tactical Map